Bone Marrow

Contact Us

OVERVIEW

The information on this website serves to provide communications intended for healthcare professionals (HCPs) related to unapproved uses of approved products. This information and its associated contents are to be used for educational purposes only and are not intended for promotional purposes.

Safety Information

The ACP Max™ and Angel® systems have not been approved for use in the applications below, including but not limited to osteoarthritis (OA) and soft-tissue pathologies. Current indications for the ACP Max and Angel systems include the use of PRP intraoperatively at the point of care for the safe and rapid preparation of autologous platelet concentrate (platelet-rich plasma [PRP]) from a small sample of peripheral blood or a small sample of a mixture of peripheral blood and bone marrow. The PRP may be mixed with autograft and/or allograft bone prior to application to a bony defect for improving handling characteristics. Contraindications include blood supply limitations and previous infections, which may delay healing, and/or any active infection or blood supply limitations. Adverse events can include infections, both deep and superficial, allergies and other reactions to device materials, hematoma, damage to blood vessels, and nerve damage resulting in pain or numbness from autologous sampling and/or delayed wound healing. Healthcare professionals should exercise clinical judgment and consider FDA-approved treatments before recommending bone marrow injections for the applications below.

SIUU Communications

0
Filters
page_info

All

Literature

Scientific Updates

Filter

close

Literature Type

CPG

Society Communication

Technology Overviews

Arthrex

View more

Product Category

Knee

Foot and Ankle

Hand and Wrist

Upper Extremities

Hip

View more

Resource Types

Literature

Scientific Updates

View more

Literature

Scientific Literature Updates by Product and Procedure

Important Safety Information

Indications

expand_more

Indications for the ACP Max System:

The ACP Max platelet-rich plasma (PRP) system is indicated for the safe and rapid preparation of autologous PRP from a small sample of peripheral blood or a small mixture of blood and bone marrow at the patient’s point of care. The PRP may be mixed with autograft and/or allograft bone prior to application to a bony defect for improving handling characteristics.

‍

Indications for the Angel PRP System:

‍
Kits are to be used intraoperatively at the point of care for the safe and rapid preparation of autologous platelet-poor plasma and platelet concentrate (platelet-rich plasma) from a small sample of peripheral blood or a small sample of a mixture of peripheral blood and bone marrow. The platelet-poor and -rich plasmas may be mixed with autograft and/or allograft bone prior to application to a bony defect for improving handling characteristics.

Contraindications

expand_more

ACP Max System:‍

  1. Blood supply limitations and previous infections, which may retard healing.
  2. Any active infection or blood supply limitations.

Angel System:‍

  1. Blood supply limitations and previous infections, which may retard healing.
  2. Any active infection or blood supply limitations.
  3. Conditions that tend to limit the patient's ability or willingness to restrict activities or follow directions during the healing period.
  4. Do not use for surgeries other than those indicated.

Warnings

expand_more

Federal law restricts this device to sale by or on the order of a physician. This device is intended to be used by a trained medical professional. Do not resterilize or reuse the sterile devices. Follow the manufacturer’s instructions when using centrifuge. Use only benchtop centrifuges with swing-out rotors that securely accommodate the ACP Max PRP system (eg, Rotofix 32 A benchtop centrifuge or Drucker Horizon Flex). Outcomes using other types of centrifuges are unknown. Follow the manufacturer’s directions provided with the package insert for the anticoagulant citrate dextrose A solution (ACD-A). The safety and effectiveness of this device for bone healing and hemostasis have not been established. PRP must be used within 4 hours of blood collection. This is a single-use device. Reuse of this device could result in failure of the device to perform as intended and could cause harm to the patient and/or user. Failure to use this device in accordance with the Directions for Use below may result in device failure, render the device unsuitable for its intended use, or compromise the procedure. ACD-A anticoagulant and PRP prepared are not for intravenous use. For additional information on ACD-A anticoagulant, refer to the component label. Biohazard waste, such as explanted devices, needles, and contaminated surgical equipment, should be safely disposed of in accordance with the institution’s policy. Serious incidents should be reported to Arthrex, Inc. or an in-country representative, and to the health authority where the incident occurred. Some blood contacting components of the device have been sterilized with ethylene oxide, which can cause serious allergic reactions in some sensitized individuals.

‍

ACP Max System:

Caution: Federal law restricts this device to sale by or on the order of a physician.

  1. This device is intended to be used by a trained medical professional.
  2. Do not resterilize this device.
  3. Do not reuse this device.
  4. Follow the manufacturer’s instructions when using centrifuge. Use only benchtop centrifuges with swing-out rotors that securely accommodate Arthrex ACP double-syringes and ACP Max PRP system (eg, Rotofix 32 A benchtop centrifuge or Drucker Horizon Flex). Outcomes using other types of centrifuges are unknown.
  5. Follow the manufacturer’s directions that are provided with the package insert for the anticoagulant citrate dextrose A solution (ACD-A).
  6. The safety and effectiveness of this device for bone healing and hemostasis have not been established.
  7. The PRP must be used within four (4) hours of blood collection.
  8. This is a single-use device. Reuse of this device could result in failure of the device to perform as intended and could cause harm to the patient and/or user.
  9. Failure to use this device in accordance with the Directions for Use below may result in device failure, render the device unsuitable for its intended use, or compromise the procedure.
  10. ACD-A anticoagulant and PRP prepared are not for intravenous use. For additional information on ACD-A anticoagulant, refer to the component label.
  11. Biohazard waste, such as explanted devices, needles, and contaminated surgical equipment, should be safely disposed of in accordance with the institution’s policy.
  12. Serious incidents should be reported to Arthrex, Inc. or an in-country representative, and to the health authority where the incident occurred.
  13. Some blood contacting components of the device have been sterilized with ethylene oxide, which can cause serious allergic reactions in some sensitized individuals.

‍

Angel System:

Caution: Federal law restricts this device to sale by or on the order of a physician.

  1. This device is intended to be used by a trained medical professional.
  2. Do not resterilize this device.
  3. Do not reuse this device or any of its components.
  4. Failure to use this device in accordance with the Directions for Use below may result in device failure, render the device unsuitable for its intended use, or compromise the procedure. 
  5. Preoperative and operating procedures, including knowledge of surgical techniques and proper selection and placement of the device, are important considerations in the successful utilization of this device. 
  6. A device labeled as a single-use device must never be reused. Reuse may pose health and/or safety risks to the patient that can include, but are not limited to, cross-infection, breakage resulting in irretrievable fragments, compromised mechanical performance due to wear, lack of or no function, no guarantee of proper cleaning or sterilization of the device. 
  7. Biohazard waste, such as explanted devices, needles, and contaminated surgical equipment, should be safely disposed of in accordance with the institution’s policy.
  8. Serious incidents should be reported to Arthrex, Inc. or an in-country representative, and to the health authority where the incident occurred.

Potential Adverse Events

expand_more

ACP Max System:

  1. Infections, both deep and superficial
  2. Allergies and other reactions to device materials
  3. Hematoma
  4. Damage to blood vessels and nerve damage resulting in pain or numbness from autologous sampling
  5. Delayed wound healing

Angel cPRP System:

  1. Infections, both deep and superficial
  2. Foreign body reactions
  3. Hematoma

Need more information?

Connect with our team for additional information and educational support.

Contact Us
close

Have questions or need assistance? Reach out to our Clinical Advisory team (CAT) via email.

Contact Us

Have questions or need assistance? Reach out to our Clinical Advisory team (CAT) via email. Send the team an email (CAT@arthrex.com), and they will respond within 1-2 business days.

‍

Copy Email
Open Email